EasyUC Engineer
Inventory, comparison and diagnostic imports
Capture the CUCM inventory, compare two states field by field, export and analyse existing log files locally.
In EasyUC: Inventaraufnahme; Vergleich & Export; Diagnoseimporte
What it is for
An inventory records the configured state of a CUCM: devices, users, numbers and patterns, line groups, pickup groups and trunks. Two inventories of the same connection show what an assignment changed. Inventories remain available even after the connection profile is removed.
Diagnostic imports analyse existing UTF-8 logs, text, CSV and JSON files locally. Cisco CDRs are counted as call legs; selected TLS, DNS, timeout and SIP messages get hints with their locations.
Prerequisites
- A verified CUCM connection with AXL read permissions (for inventories).
- For diagnostic imports: the files to analyse on your computer.
Step by step
Fields and options
| Field / action | Meaning and use |
|---|---|
| Inventory areas | Phones & devices, users, lines, groups and trunks. |
| CSV export | Leading zeros are kept; cells that start like formulas are neutralised. |
| Diagnostic samples | Detected password and token patterns are removed. This is not a complete anonymisation of arbitrary log files. |
Check the result and narrow down errors
- An inventory shows configuration, not live status. Current registrations come from the reports or the server services.
- Diagnostic imports provide hints from the file; they do not replace measurements and do not prove a root cause.